Sikadur®-53 UF Grout is a 3-part high performance, high early strength, solvent free, moisture tolerant pourable epoxy grout. It has good flowability, low shrinkage, good mechanical strengths and is suitable for many static or dynamic precision grouting applications. Also suitable as a flowable concrete repair material. Specially designed for grouting in under water / wet conditions. When it is poured into the cavity, it displaces the water and cures to a rigid high strength material.
Part A+B+C pre-batched | 11 kg set |
Part A | 2 kg container |
Part B | 1 kg container |
Part C | 8 kg bag |
Chemical base
Epoxy resin and selected fillers and aggregates
Shelf life
12 months from date of production
Storage conditions
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +40 °C. Protect from direct sunlight.
Compressive strength
Curing time | Compressive strength |
3 h | ≥ 20 N/mm2 |
6 h | ≥ 40 N/mm2 |
1 d | ≥ 60 N/mm2 |
7 d | ≥ 80 N/mm2 |
Test specimens cured at +30 °C under water
Tensile adhesion strength
> 10 N/mm2 | (ASTM C882) |
Test specimens cured at +30 °C under water
Mixing ratio
Part A : Part B : Part C = 2 : 1 : 8 (by weight)
Fresh mortar density
1.9 ± 0.1 kg/L (Part A+B+C mixed, +27 °C) | (EN ISO 2811-1)
|
Layer thickness
Maximum | 50 mm per layer |
Minimum | 10 mm |
Additional layer thickness can be applied in successive layers once each layer has cooled and hardened sufficiently. The last layer of a multiple pour must be at least 50 mm.
Product temperature
Condition the material between +10 °C and +30 °C for 48 hours before use.
Ambient air temperature
+10 °C min. / +40 °C max.
Dew point
Beware of condensation.
The substrate and uncured applied product must be at least +3 °C above dew point to reduce the risk of condensation.
Substrate temperature
+10 °C min. / +40 °C max.
Pot life
> 20 minutes (100 g mass, +30 °C) | (FIP 5.1) |
Pot life begins when all parts have been mixed. It is shorter at high temperatures and longer at low temperatures. The greater the quantity mixed, the shorter the pot life. To obtain longer workability at high temperatures, chill parts A+B before mixing (i.e. only when application temperatures are above +20 °C).
SUBSTRATE QUALITY
Concrete
Steel
SUBSTRATE PREPARATION
Concrete
Steel
Shutter Formwork
MIXING
Note: Mix only the quantity which can be used within its pot life.
Note: Always mix part A and B by adding part C (this prevents an exothermic reaction between A and B which generates excess heat).
CLEANING OF TOOLS
Clean all tools and application equipment with Sika® Colma Cleaner immediately after use. Hardened material can only be removed mechanically.