Sikaflex®-11 FC+

One part advanced polyurethane, elastomeric sealant/adhesive

Sikaflex®-11 FC+ is a one-component, gun-grade, adhesive and sealing compound of permanent elasticity. This dual-purpose material is based on a special moisture-cured polyurethane with an accelerated curing time that meets ASTM C920 Type S, Grade NS, Class 12.5, Use NT, I, M, A, O. and Federal Specification TT-S-00230C, Type II, Class B.

Usage

As an elastic adhesive for noncritical applications like:

As an elastic joint sealer for:

Packaging

10.1 fl. oz. (300 ml) cartridge, 20 fl. oz. (600 ml) sausage, 4.5 gal (17 L) in a 5 gal pail

Advantages

Colour

White, Aluminum Gray, Black

Product Details

APPROVALS / STANDARDS
  • ASTM C920 Type S, Grade NS, Class 12.5, Use NT, I, M, A, O
  • Federal Specification TTS-00230C, Type II, Class B
  • Certified to NSF/ANSI/CAN 61 for potable water (meets applicable requirements of NSF/ANSI 600).

Shelf Life

12 months in unopened container.

 

Storage Conditions

Store at 40–95 °F (4–35 °C).

Condition material to 65–75 °F before using.

 

Volatile organic compound (VOC) content


25 g/L

Shore A Hardness


40–45(73 °F (23 °C) and 50 % R.H.) (ASTM D-2240)

 

Tensile Strength


225 psi(73 °F (23 °C) and 50 % R.H.) (ASTM D-412)

 

Lap Shear Strength


165 psi

(73 °F (23 °C) and 50 % R.H.) (ASTM D-1002

modified, glass substrate)

 

Elastic Recovery


>90 %(73 °F (23 °C) and 50 % R.H.) (ASTM C-719)

 

Service Temperature


-40 °F to 170 °F

 

Chemical Resistance


Good resistance to water, weak acids, weak alkalis, sewerage, mineral oils, vegetable oils, fats, fuels. (Not resistant to organic solvents, paint thinner, strong acids, strong alkalis). Consult Technical Service for specific data.

 

Resistance to Weathering


Excellent

Application

Ambient Air Temperature


40 °F to 100 °F.

Sealant should be installed when joint is at mid-range of its anticipated movement.

 

Curing Rate


Tack-free Time (TT-S-00230C)1 to 2 hours depending on climate
Final Cure3 to 5 days
 

Coverage


Width/Depth1/4”3/8”1/2”
1/4”24.3  
3/8”16.210.8 
1/2”12.18.16.1
3/4”8.15.44.0
1”  3.0
1.25”  2.4
1.5”  2.0

SUBSTRATE PREPARATION


Clean all surfaces. Joint walls must be sound, clean, dry, frost-free, and free of oil and grease. Curing compound residues and any other foreign matter must be thoroughly removed. A roughened surface will also enhance bond. Bond breaker tape or backer rod must be
used at bottom or base of joint void to prevent three
sided adhesion.

  

Priming


Priming is not usually necessary for anodized aluminum, steel, non-absorbent materials such as glass, ceramics, stoneware and tiles. Most substrates only require priming if testing indicates a need or where sealant will be subjected to water immersion or chemical exposureafter cure. Consult Technical Service at 1-800-933-SIKA for additional information on priming.



Document