Single rolls packed in vacuum foil. Multiple single rolls packed in cardboard boxes. Refer to current price list for packaging variations.
Profile after swelling (left) and before swelling (right)
ENVIRONMENTAL INFORMATION
APPROVALS / STANDARDS
Acrylic polymer
Shelf Life
36 months from the date of production
Storage Conditions
The product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5 °C and +35 °C. Always refer to packaging.
Density
1.50 kg/l (at +23 °C) | (EN ISO 2811-1) |
Dimensions
Type | Width | Height | Length |
SikaSwell® A 2005 | 20 mm | 5 mm | 20 m |
SikaSwell® A 2010 | 20 mm | 10 mm | 10 m |
SikaSwell® A 2015 | 20 mm | 15 mm | 7 m |
SikaSwell® A 2025 | 20 mm | 25 mm | 5 m |
Adhesive | SikaSwell® S-2 |
Swelling profile | SikaSwell® A |
Shore A hardness
(10 ± 5) | (DIN 53505) |
Change of volume
Time | Demineralised water |
1 day | ~50 % |
7 days | ~130 % |
30 days | ~150 % |
Note: Swelling properties in saline water will be reduced and delayed. Use SikaSwell® A Maritim version.
Note: In a totally dry state the Product shrinks to its original dimensions. The product then expands again upon further contact with water.
Swelling pressure
The pressure developed by the material depends on the stiffness of the surrounding concrete structure, which is influenced by the concrete quality, voids, gaps and other weaknesses.
Note: In an ideal concrete structure the material can develop a swelling pressure up to > 10 bar.
Service temperature
Maximum | +50 °C |
Minimum | -20 °C |
Substrate moisture content
Dry or matt damp. Do not apply in construction joints with existing standing water.
Ambient air temperature
Maximum | +35 °C |
Minimum | +5 °C |
Substrate temperature
Maximum | +35 °C |
Minimum | +5 °C |
SUBSTRATE QUALITY
The substrate must be sound, clean, dry or matt damp, free from all surface contaminants that could impair the adhesion.
SUBSTRATE PREPARATION
EXISTING CONCRETE
Rough surfaces are susceptible to leaking. If the surface roughness cannot be leveled with SikaSwell® S-2 the roughness need to be removed by an appropriate Sika leveling mortar or mechanical treatment before the SikaSwell® S-2 and SikaSwell profile is applied.
FRESHLY CAST CONCRETE
Freshly cast concrete can be smoothed with a batten where SikaSwell® S-2 is to be placed.
APPLICATION
IMPORTANT
Concrete cover
Insufficient concrete cover, low density concrete or voids will prevent the SikaSwell® profile from developing its waterproofing function.
SEALANT WITH A SIKASWELL® PROFILE
CLEANING OF TOOLS
Clean all tools and application equipment immediately after use with Sika® Colma Cleaner. Hardened material can only be removed mechanically.