The product is used for adhering SikaShield® W membranes for waterproofing in:
Chemical base
Polymer modified cement
Shelf life
12 months from date of production
Storage conditions
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +35 °C.
System structure
Layer | Product |
1. Adhesive | SikaShield® W1 IN |
2. Membrane | SikaShield® W159 ED 1,5 mm |
3. Protection | Suitable protection layer |
Mixing ratio
water : powder = 0.33–0.37
~9.9–11.1 L of water per 30 kg bag
Fresh mortar density
~1.95 kg/L | (EN ISO 2811-1) |
Layer thickness
Minimum | 1 mm |
Maximum | 3 mm |
Ambient air temperature
+10 °C min. / +40 °C max.
Substrate temperature
+10 °C min. / +40 °C max.
Pot life
≥ 30 minutes (100 g mass, +25 °C, 65 % r.h)
Consumption
~2.0–3.0 kg/m2 (wet adhesive consumption per m2 of membrane)
Note: Consumption data is theoretical and does not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.
EQUIPMENT
MIXING
APPLICATION
SUBSTRATE QUALITY
SYSTEM DESIGN
When designing the waterproofing system, make sure that the supporting structure has sufficient structural strength to support all new and existing layers of the system build-up. New concrete substrates must be at least 3 days old.
SUBSTRATE CONDITION
The substrate surface must be uniform, firm, smooth and free of any sharp protrusion or burrs, clean, dry, free of grease, laitance, oil, dust and loosely adhering particles.
MIXING
IMPORTANT
Over addition of water
Do not add more than prescribed water to the powder. Over addition affects the product’s finished mechanical performance.
Note: If mix has thickened due to delayed application, DO NOT dilute further with water. This should be discarded.
APPLICATION
Note: Allow for minimum 24 h curing (at +25 °C) of the SikaShield® W1 IN prior to backfilling the installed SikaShield® W waterproofing membrane.
CLEANING OF TOOLS
Clean all tools and application equipment with water immediately after use. Hardened material can only be removed mechanically.