Sarnafil® G 410-15 L Felt

Polymeric membrane for adhered roof waterproofing

Sarnafil® G 410-15 L Felt (thickness 1.5 mm) is a multi-layer, synthetic roof waterproofing sheet based on polyvinyl chloride (PVC) with a glass non-woven inlay and polyester fleece backing. It contains ultraviolet light stabilisers according to EN 13956 / GB 12952. Sarnafil® G 410-15 L Felt is a hot-air weldable roof membrane, formulated for direct exposure and designed for use in all global climatic conditions.

Usage

Sarnafil® G 410-15 L Felt may only be used by experienced professionals. Waterproofing membrane for:

Packaging

Standard rolls are wrapped individually in a blue PE-foil.

Length

20.00 m

Width

2.00 m

Weight86.00 kg

Advantages

Colour

Surfacematt
Colours

 

Top Surfacewhite
Bottom surfacedark grey

 

Top surface colour available in other colours subject to minimum order quantities.

Product Details

ENVIRONMENTAL INFORMATION


  • Conformity with LEED v4 MRc 3 (Option 2): Building Product Disclosure and Optimization – Sourcing of Raw Materials
  • Conformity with LEED v4 MRc 4 (Option 2): Building Product Disclosure and Optimization – Material Ingredients

 

APPROVALS / STANDARDS


  • CE Marking and Declaration of Performance to EN 13956 – Polymeric sheets for roof waterproofing
  • GB 12952, Sarnafil® G 410-15 L Felt, Test report No. RS19-21

Chemical Base


Polyvinyl Chloride (PVC)

 

Shelf Life


5 years from date of production.

 

Storage Conditions


Product must be stored in original unopened and undamaged packaging in dry conditions and temperatures between +5 °C and +30 °C. Store in a horizontal position. Do not stack pallets of the rolls on top of each other, or under pallets of any other materials during transport or storage. Always refer to packaging.

 

Product Declaration


EN 13956 – Polymeric sheets for roof waterproofing

GB 12952 – Type GL

 

Visible Defects


Pass

(EN 1850-2)

 

Length


15.00 m (-0 / +5 %)

(EN 1848-2)

 

Width


2.00 m (-0.5 / +1 %)

(EN 1848-2)

 

Effective Thickness


1.5 mm (-5 / +10 %)

(EN 1849-2)

 

Overall Thickness


1.5 mm (-5 / +10 %)

(GB 12952)

 

Straightness


≤ 30 mm

(EN 1848-2)

 

Flatness


≤ 10 mm

(EN 1848-2)

 

Mass per Unit Area


2.15 kg/m² (-5 / +10 %)

(EN 1849-2)

System Structure

The following products must be considered for use depending on roof design:

  • Sarnafil® G 410-12 L sheet for detailing
  • Sarnafil® Metal Sheet PVC
  • Sarnabar® or S-U Bar
  • Sarna Seam Cleaner
  • Sarnacol® 2170 / 2142 / 2152 Adhesive
  • Sarna Cleaner

Ancillary Products:

 

Prefabricated parts, roof drains, scuppers, walkway pad, decor profiles, protection sheets.

 

Compatibility


Not compatible in direct contact with bitumen, tar, fat, oil, solvent containing materials and other plastic materials, e.g. expanded polystyrene (EPS), extruded polystyrene (XPS), polyurethane (PUR), polyisocyanurate (PIR) or phenolic foam (PF). These materials could adversely affect the product properties.

 

Resistance to Impact


hard substrate

≥ 700 mm

soft substrate

≥ 1300 mm

 

watertight

(GB/T20624.2)

 

 

Hail Resistance


rigid substrate

≥  17 m/s

flexible substrate

≥  25 m/s

 

 

Resistance to Static Load


soft substrate

≥ 20 kg

rigid substrate

≥ 20 kg

 

watertight

(GB/T328.25)

 

 

Tensile Strength


longitudinal (md)1)

≥  650 N/50 mm

transversal (cmd)2)

≥  650 N/50 mm

 

≥ 120 N/cm

(GB/T328.9)

 

1) md =      machine direction
2) cmd =    cross machine direction

 

Elongation


longitudinal (md)1)

≥ 45 %

transversal (cmd)2)

≥ 45 %

 

≥ 100 %

(GB/T328.9)

 

1) md =      machine direction
2) cmd =    cross machine direction

 

 

Dimensional Stability


longitudinal (md)1)

≤ |0.2| %

transversal (cmd)2)

≤ |0.2| %

 

≤ 0.1 %

(GB/T328.13)

 

1) md = machine direction
2) cmd = cross machine direction

 

Tear Strength


≥  220 N

(GB/T328.19)

 

Joint Peel Resistance


Failure mode: C, no failure of the joint

(EN 12316-2)

≥  3 N/mm

(GB/T328.21)

 

Joint Shear Resistance


≥  500 N/50 mm

(EN 12317-2)

 

Foldability at Low Temperature


≤  -25 °C

(EN 495-5)

no crack

(GB/T328.15)

 

Reaction to Fire


Class E

(EN ISO 11925-2, classification to EN 13501-1)

E

(GB 8624 / EN 13501-1)

 

Effect of Liquid Chemicals, Including Water


Tensile strength retention≥  85 %
Elongation retention≥  80 %
Low temperature bendno crack

 

Retention of Properties after Heat Ageing


Tensile strength retention≥  85 %
Elongation retention≥  80 %

Low temperature bend

no crack

 

Resistance to UV Exposure


Pass (> 5000 h / grade 0)

(EN 1297)

 

Artificial Ageing


Tensile strength retention≥  85 %
Elongation retention≥  80 %

Low temperature bend

no crack

 

Water Absorption


wet weight≤  4 %
dry weight≥  -0.4%

 

Water Tightness


 

Pass

(EN 1928)

 

Watertight

(GB/T328.10)

 

Solar Reflectance


0.80

(GJB 2502.2)

 

Solar Reflectance Index


106 (white, initial)

(ASTM E 1980)

Application

Ambient Air Temperature


-20 °C min. / +60 °C max.

 

Substrate Temperature


-30 °C min. / +60 °C max.

EQUIPMENT


Hot welding overlap seams
Electric hot air welding equipment, such as hand held manual hot air welding equipment and pressure rollers or automatic hot air welding machines with controlled hot air temperature capability of a minimum +600 °C.
Recommended type of equipment:

  • Manual: Leister Triac
  • Semi-automatic: Leister Triac Drive
  • Automatic: Sarnamatic 681/ Leister Varimat

 

SUBSTRATE QUALITY


The substrate surface must be uniform, smooth and free of any sharp protrusions or burrs, etc. Sarnafil® G 410-15 L Felt must be separated from any incompatible substrates / materials by an effective separation layer to prevent accelerated ageing. The supporting layer must be compatible to the membrane, solvent resistant, clean, dry and free of grease and dust. Metal sheets must be degreased with Sarna Cleaner before adhesive is applied.

 

APPLICATION


Installation procedure
Strictly follow installation procedures as defined in method statements, application manuals and working instructions which must always be adjusted to the actual site conditions.

 

Fully bonded roof surfaces and detailing

The roof waterproofing membrane is bonded to the substrate using a Sarnacol® adhesive. The type of adhesive is selected based on the type and slope of substrate. Refer to the individual Sarnacol® adhesive Product Data Sheet.

 

Hot welding method
Overlap seams must be welded by electric hot welding equipment. Welding parameters including temperature, machine speed, air flow, pressure and machine settings must be evaluated, adapted and checked on site according to the type of equipment and the climatic conditions prior to welding.

 

Testing overlap seams
The seams must be mechanically tested with screw driver (rounded edges) to ensure the integrity/completion of the weld. Any imperfections must be rectified by hot air welding.

Document