Sika® ViscoCrete®-2002 HE

High Performance Superplasticizing Admixture

Imparts very high workability, allows a large reduction in water content and gives high early strength.

Sika® ViscoCrete®-2002 HE produces a more uniformly cohesive high quality free flowing concrete Sika® ViscoCrete®-2002 HE will result in the following advantages of concrete:

Usage

Sika® ViscoCrete®-2002 HE a superplasticizer for free flowing concrete in floors, slabs, foundations, slender components with dense re inforcement, walls and columns and other structural elements. Sika® ViscoCrete®-2002 HE is mainly used for the following types of concrete:

Packaging

255 kg drums /Bulk supply

Advantages

Colour

Brown Hazy Liquid

SikaCim® is recommended for use in structural concrete, particularly for the following

Product Details

APPROVALS / STANDARDS

IS 9103, ASTM C494

Chemical Base

Aqueous solution of modified poly carboxylate

Shelf Life
12 months from date of production if stored properly in undamaged unopened, original sealed packaging.

Storage Conditions
Store in dry conditions at temperatures between +10°C and +40°C. Protect from direct sunlight and frost.

Density
~1.08 kg/l at 25°C

pH-Value
≥ 6

Application

Compatibility

Sika ViscoCrete -2002 HE may be combined with many other Sika® Products.

It is compatible with all types of ordinary Portland cement, PPC, PSC and cement replacement materials.

Important: Always conduct trials before combining products in specific mixes and contact our Technical Service Department for information about specific combinations.

DISPENSING

Sika ViscoCrete -2002 HE can be added into the mixing water or directly into the concrete mixer after 50 – 70% of the mixing water has been added.

The addition of Sika ViscoCrete -2002 HE to dry aggregate or cement is not recommended.

To achieve optimum performance a minimum wet mixing time, which is depending on the mixing conditions and the mixer performance, of 60 seconds is recommended.

Recommended Dosage

Optimum dosage of Sika® ViscoCrete®-2002 HE should be determined by site trials.

Recommended dosage:  0.2 – 2.0% by weight of cementitious.