SikaSwell® A

Hydrophilic swellable joint sealing profiles

SikaSwell® A is a rectangular acrylic sealing profile. It swells in contact with water to seal all types of construction joints and penetrations in concrete structures.

Usage

Joint sealing:

Packaging

Single rolls packed in vacuum foil. Multiple single rolls packed in cardboard boxes. Refer to current price list for packaging variations.

Advantages

Colour

Profile after swelling (left) and before swelling (right)

Product Details

ENVIRONMENTAL INFORMATION


  • Conforms with LEED v4 MR credit: Building product disclosure and optimization — Material ingredients (option 2)

 

APPROVALS / STANDARDS


  • Resistance to water pressure and durability SikaSwell® A2010, SikaSwell® S-2, BBA, Certificate No.13/4994
  • Functional watertightness test, SikaSwell® A, WISSBAU, Test report No. 2012-206
Chemical Base

Acrylic polymer

 

Shelf Life
36 months from the date of production

 

Storage Conditions
The product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5 °C and +35 °C. Always refer to packaging.

 

Density

1.50 kg/l (at +23 °C)

(EN ISO 2811-1)

 

Dimensions


Type

Width

Height

Length

SikaSwell® A 2005

20 mm

5 mm

20 m

SikaSwell® A 2010

20 mm

10 mm

10 m

SikaSwell® A 2015

20 mm

15 mm

7 m

SikaSwell® A 2025

20 mm

25 mm

5 m

System structure

Adhesive

SikaSwell® S-2

Swelling profile

SikaSwell® A



Shore A hardness


(10 ± 5)

(DIN 53505)

 

Change of volume


Time

Demineralised water

1 day

~50 %

7 days

~130 %

30 days

~150 %

Note: Swelling properties in saline water will be reduced and delayed. Use SikaSwell® A Maritim version.

Note: In a totally dry state the Product shrinks to its original dimensions. The product then expands again upon further contact with water.

 

Swelling pressure


The pressure developed by the material depends on the stiffness of the surrounding concrete structure, which is influenced by the concrete quality, voids, gaps and other weaknesses.

Note: In an ideal concrete structure the material can develop a swelling pressure up to > 10 bar.

 

Service temperature


Maximum

+50 °C

Minimum

-20 °C

Application

Substrate moisture content


Dry or matt damp. Do not apply in construction joints with existing standing water.

 

Ambient air temperature


Maximum

+35 °C

Minimum

+5 °C

 

Substrate temperature


Maximum

+35 °C

Minimum

+5 °C

SUBSTRATE QUALITY


The substrate must be sound, clean, dry or matt damp, free from all surface contaminants that could impair the adhesion.

 

SUBSTRATE PREPARATION


EXISTING CONCRETE

Rough surfaces are susceptible to leaking. If the surface roughness cannot be leveled with SikaSwell® S-2 the roughness need to be removed by an appropriate Sika leveling mortar or mechanical treatment before the SikaSwell® S-2 and SikaSwell profile is applied.

 

FRESHLY CAST CONCRETE

Freshly cast concrete can be smoothed with a batten where SikaSwell® S-2 is to be placed.

 

APPLICATION


IMPORTANT

Concrete cover

Insufficient concrete cover, low density concrete or voids will prevent the SikaSwell® profile from developing its waterproofing function.

  1. Place the SikaSwell® profile in the centre of the concrete structure.
  2. In reinforced concrete maintain a minimum cover of 8 cm on both sides.
  3. In unreinforced concrete maintain a minimum cover of 15 cm on both sides.

SEALANT WITH A SIKASWELL® PROFILE

  1. Apply SikaSwell® S-2 adhesive in a narrow bed (size of triangular section ~12 mm tall and ~12 mm wide ) onto the prepared substrate. Extrude enough material to level the roughness of the substrate.
  2. Press the SikaSwell® profile firmly into the fresh applied SikaSwell® S-2. Place the SikaSwell® profile within a maximum of 30 minutes (+23 °C / 50 % r.h.).
  3. Ensure full and continuous contact between the SikaSwell® S-2 and both the SikaSwell® profile and the substrate is achieved.
  4. Allow SikaSwell® S-2 to harden minimum 12 hours before placing concrete. For pouring height > 50 cm, SikaSwell® S-2 must harden for at least 24 hours before placing concrete.
  5. Protect the SikaSwell® S-2 and the SikaSwell® profile against water (for example, rain) until the concrete is placed.
  6. During placement compact the fresh concrete well around the SikaSwell® profile to achieve dense concrete without any honeycombing or voids.

 

CLEANING OF TOOLS


Clean all tools and application equipment immediately after use with Sika® Colma Cleaner. Hardened material can only be removed mechanically.